Sized from data, not datasheets
GPU memory decides which models you can run; memory bandwidth and batch size decide how many people they can serve. We size from your measured token volumes and peak concurrency, then leave headroom for the adoption growth that always follows once tokens stop being metered.
| Tier | Typical configuration | Serves | Facility |
|---|---|---|---|
| Team | 1 server · 4× RTX PRO 6000 Blackwell · 384 GB | 5–30 heavy users | Comms room, ~2.2 kW, air |
| Department | 1–2 servers · 8× RTX PRO 6000 or H200 NVL · 768 GB+ | 30–100 users | Standard rack, ~4–8 kW |
| Enterprise | HGX B200 / B300 nodes · 1.4–2.3 TB HBM3e each | 100–5,000+ users | Data centre or colo, ~14 kW per node |
| Edge & prototype | DGX Spark · DGX Station · RTX workstations | Labs, branches, PoC | Desk-side |
Scope of delivery
- ProcurementVendor-neutral sourcing through NVIDIA partner OEMs, lead-time management
- Facility readinessPower, cooling, rack and floor-load checks with your facilities team
- NetworkingInfiniBand or Spectrum-X Ethernet fabrics, storage and management networks
- PlatformKubernetes, NVIDIA GPU Operator, container registry, secrets and storage
- Burn-in72-hour stress test, thermal validation and performance baselines
- ObservabilityDCGM, Prometheus and Grafana dashboards, alerting into your tools
Where it can live
Smaller configurations run in a standard comms room with normal power and air cooling. Larger clusters go into your own data centre or a colocation facility of your choice. In every case you own the hardware and hold the keys. For organisations with no on-site capacity, we can arrange dedicated hardware in a European colocation facility under your contract.
Built for high availability
Production platforms are designed with no single point of failure: redundant power feeds and network paths, model replicas across nodes, and graceful degradation to a smaller model if a node is down. Multi-site designs replicate the serving tier across two locations.